Max10: ADC no longer working with .pof document

Disappointed, you need to be sure doing this action. Excite click on the confirmation link in your email address. You can also re also-send via your reputation.

  • Intel Community
  • Product Support Community forums
  • FPGA
  • Automated Equipment
  • Max10: ADC no longer working that have .pof document
  • Draw Thing because This new
  • Draw Matter due to the fact Read
  • Float this subject having Current Member

We suspect you may have one to (or more) quite sluggish otherwise below ranked supplies

I’m currently working with Max10M16DAF256 and that i struggle with the ADC. sof document it truly does work fine. pof document the newest ADC doesn’t work anymore, i.age ADC info is usually zero, once the other people areas functions truthfully.

When using

You will find as well as viewed that whenever programming which have .pof file nonetheless allow the suppy current on the, this new ADC functions. However, just after reset the supply voltage (turn fully off as well as on once again), it will not performs any further.

Should your latter you will need to verify look at the method that you discharge the ADC Internet protocol address out-of reset. Wait in reset ‘a little longer’ following pump up. Sorry this may voice a tiny vague. This is apparently an everyday procedure to your forum one does not seem to have received an obvious, reputable service.

If this is their board you will need to evaluate the above and ensure the newest rail rise monotonically. There are not any sequencing conditions however, if the never increase correctly – maybe not appointment the new Tramp day – the device will misbehave. Reference ‘Figure 3. Tracked Energy Supplies Ramp Up’ throughout the ‘ energy government user publication (

I also receive a comparable trouble with Max10 ADC an additional bond, however, like you said there is absolutely no service for this.

The latest board was our very own mind construction board. The issue is that many of our forums Chita in Russia marriage agency are working good with “ .pof „-document, and lots of of these have this ADC condition. To the forums which have ADC situation, we examined in the equipment of them boards regrettably i missed any issue for the resources. Including listed above, the new chatrooms work which have “ .sof “ plus “ .pof „-document in the event the supply voltage is always for the. Pursuing the also provide current is reset, this new ADC does no longer work due to the fact other individuals continues to be functioning accurately.

This will make me personally faith way more this matter is generally power related. You happen to be clearly to your side of regardless of the concern is offered you may have doing work chat rooms.

Can you bring a low operating board, disconnect the benefit offers and you may energy it regarding workbench supplies? My personal concern is you to a lower than rated train is not doing giving the inrush requisite and you can dips evoking the POR circuitry a state, which (perhaps) is not reported.

You will be correct. I did so specific analysis in the stamina offers to own Max10, plus it appears like all of our analog also provide requires a little enough time until they are at full voltage top (our company is having fun with Max10 twin also have equipment, which demands a couple electronic offers and you may step one analog likewise have).

As with Max10 Electricity management associate guide, it appears as though just the past battery having Max10 matter (attached visualize), so we attempted to swtich toward analogue also have earliest and you may watch for it to arrive max peak, and then turn on another two digital provides, hence get only couple hundred or so µs to arrive max peak. This will help to the newest perhaps not-doing work ADC being operating sporatically (not always functioning).

But when we take a working panel (ADC constantly performs) and you can do the opposite sequence (i.age assist two electronic supplies into the basic, then analogue also have), new ADC remains performing (we expected so it cannot really works any longer).

Very somehow the fresh new ADC condition means the benefit also have series and the ramp duration of strength offers, but a very clear reason for this state has been maybe not discovered but really.